TDW Provides Support for ESDV Replacements Off West Africa

NIVELLES, BELGIUM, July 8, 2015 – Performing maintenance or repair on a live crude export
pipeline can be a daunting task. The steps – from product removal and depressurizing to
flooding and then de-watering the line – can be risky, costly, and complicated.


During the recent replacement of two emergency shutdown valves (ESDVs) on one of its
production platforms offshore West Africa, the operator, an independent Anglo-French oil
and gas company, not only avoided those difficulties, but also maintained production and
ensured increased safety through topside pipeline isolation for both valves. The operation
on two 8-inch & 12-inch incoming risers integrated multiple isolation methods, including
industry-standard double block and bleed technology.

esdv

ESDV valve

To isolate the 8-inch riser, a single position STOPPLE® plugging system with bypass was set
through a three-way spool. The 12-inch riser was similarly isolated via a three-way spool,
complete with bypass, but this setup allowed for use of a STOPPLE Train system, which
provided the additional safety of double block and bleed capability.

The double block and bleed technology provided by T.D. Williamson (TDW) allows two independent seals to enter the pipeline through a single hot tap opening, reducing the total number of fittings and hot taps required. A bleed port between the two seals then allows for pressure and product evacuation, which means workers performing welding or pipe cutting downstream are separated from the line’s pressurized contents.

“Although proper planning and coordination are requisite for all offshore operations,” says Fernando Pimenta, TDW Project Coordinator, “isolating topside on a production platform presents a number of unique logistical challenges.” For example, due to the limited amount of workspace on the platform, the isolation equipment had to be positioned directly below the ESDVs through a complex network of scaffolding and lifting tools. The location of the valves meant that, ultimately, all equipment was operated while positioned horizontally near the surface of the water, just a few meters from the splash zone. Throughout the four-week ESDV replacement, the operator successfully maintained production at a safe operating pressure of 15 bars (218 PSI) via bypass

 

Source: TDW Press Release